Virus Removal or Upgrade Failed
Feature paths:
- Virus removal: Open OKCARE, select the
ASICmodule →Load→ select the miner →Virus Removal. - Upgrade: Open OKCARE, select the
ASICmodule →Load→ select the miner →Upgrade.
If virus removal or an upgrade fails, check the following in order:
- Check the miner connection: Confirm that the miner is powered on, OKCARE can open its dashboard, and both power and network connections remain stable.
- Confirm the model and firmware version: Some models or firmware versions do not support online processing. For example, an S9/S9i running official 2019 firmware must be restored with an SD card.
- Restart or reset, then try again: Restart the miner before repeating the operation. If an L3+ still fails, reset it according to the model instructions and try again. Use an SD card recovery if it continues to fail.
- Use SD card recovery: If online virus removal or upgrading repeatedly fails, download firmware that matches the exact miner model and restore it with an SD card.
Do not disconnect power or network during virus removal, upgrading, or SD card recovery. Never use firmware intended for a different miner model. See ASIC Module Tutorial.
If the issue persists after these checks, contact us and provide when the issue occurred, the device or App version, the complete error message, and relevant logs. Do not send passwords, private keys, or complete verification codes.