In the OKCARE ASIC module, you can load miners and filter or sort the list by model, IP address, status, or virus infection. Supported models include L3, L3+, L3++, S9, S9i, T9, S17, T17, S19, and S19 Pro. Refer to the corresponding section of this article for the models supported by each feature. Before a batch operation, verify the selected miner count and models.

Set an IP Range and Load Miners

  1. Open the ASIC module and click + next to IP Range.
  2. Enter the IP range containing the ASIC miners.
  3. Click Load and view the discovered miners in the list.
  4. Select miners, then click Scan to refresh their status or Restart to restart them.

If no miners appear, confirm that the computer and miners are on the same LAN, the miners have started normally, and their Ethernet cables are connected. If they still do not load, try opening the miner dashboard in a browser. If the dashboard also fails to open, check the miner's network, IP address, or firmware first.

Connect to a Pool

For miners running official firmware, you can configure the pool with OKCARE's pool feature or in the miner dashboard as described below.

For miners running OKMINER firmware, configure the pool with a mining template in Miner Management in the OKMINER App. Do not use OKCARE's pool feature.

  1. On a computer on the same LAN, enter the miner IP address in a browser and sign in to the miner dashboard.
  2. Open Miner Configuration, Pool Settings, or a similarly named pool settings page.
  3. Enter a pool address under Pool 1.
  4. Under Worker or User, enter sub-account.worker-name.

    For example, if the sub-account is account01 and the worker name is l3-01, enter account01.l3-01. Use a different worker name for each miner.

  5. Password: This is a pool connection configuration field. Keep the default value shown on the page; you do not need to enter the miner web interface login password.

  6. Save or apply the settings and wait for the miner to reconnect.

If you do not have a sub-account, see Sub-account Mining.

Confirm mining after saving: Open Miner Status, Dashboard, or the status page in the miner dashboard. Confirm that the pool is connected and hashrate or accepted shares appear. After the pool receives data, open the corresponding sub-account in the OKMINER App and check the miner and hashrate.

Find and Set a Miner IP

If the miner IP address is unknown:

  1. Click IP Reporter in OKCARE.
  2. Press the ASIC miner's IP Report button.
  3. Record the address shown by OKCARE.

To change the miner IP address, click IP Settings, enter the IP address, subnet mask, gateway, and DNS, and submit. Select DHCP to obtain an address automatically or Static to set a fixed address.

The Locate function in IP Settings supports only S9, S9i, L3, L3+, and L3++. When enabled, the miner's red light stays on until the miner restarts or you click Turn Off Light.

Switch GID

Switch GID rebinds a miner running OKMINER firmware to a specified OKMINER account. If the miner has no GID, is currently bound to a GID that is not yours, or must be rebound after a firmware upgrade, enter the GID of the account that should manage the miner.

  1. Load and select the miner in the ASIC module.
  2. Click Switch GID.
  3. After binding succeeds, confirm in the OKMINER App that the miner appears under the current account.

Virus Removal

  1. Load miners in the ASIC module.
  2. Filter the list for the Virus Infection status.
  3. Select the affected miners.
  4. Click Virus Removal.
  5. Wait about 5–10 minutes, then scan again and confirm the status. Actual processing time depends on the number and status of the miners.

Do not disconnect power or network, or submit the same task repeatedly, while removal is in progress.

Access Password and Change Password

If the default miner dashboard password was changed, open Set Access Password in OKCARE and enter the dashboard password before loading miners.

If loading or scanning reports an incorrect password:

  1. Verify the miner dashboard password.
  2. Click Set Access Password and enter that same password.
  3. If the password is unknown, check the miner manufacturer's instructions for that model or firmware to find the default username, default password, and reset procedure. If a reset is required, follow those instructions, sign in with the default username and password, and change the password immediately.

To change a miner password, select the miner, click Change Password, and follow the page instructions.

OKBOOST, Overclocking, and Upgrades

OKBOOST automatically adjusts miner voltage to optimize power consumption. Select a miner and click OKBOOST to use it. This feature supports only S9, S9i, L3, L3+, and L3++ miners running OKMINER firmware.

To adjust ASIC overclocking parameters, click Overclock in OKCARE, then complete the settings in Miner Management in the OKMINER App. This button does not directly change overclocking parameters within OKCARE.

To upgrade OKMINER firmware online:

  1. Set the miner IP Range in OKCARE and click Load.
  2. Select the miners to upgrade. For a batch, select only the same model.
  3. Click Upgrade and select OKMINER firmware that matches the model.
  4. Wait for the upgrade and restart to finish. Load the miners again and verify the model, firmware version, and online status.

After upgrading OKMINER firmware, bind the miner to your GID again by following “Switch GID” on this page.

After successful binding, the model is shown as model + Plus (firmware version) and the User ID shows your account GID. The version in parentheses changes with firmware updates. Only after binding can the miner be viewed and managed remotely in the OKMINER App.

Create an SD Card and Uninstall

To flash OKMINER OS with an SD card:

Creation Erases Data

Creating the flashing SD card erases all data on the selected card. Before you begin, back up any data you need to keep and confirm that you have selected the intended SD card.

  1. Prepare a 4 GB or larger SD card, a single-slot card reader, and a computer running Windows 7 or later.
  2. Insert the SD card.
  3. Click Create SD in OKCARE.
  4. Select the miner model and confirm to begin copying firmware.
  5. When copying finishes, insert the SD card into the miner and restart it.

Do not remove power or the card during flashing. Indicators and completion behavior vary by model; follow the current page and model instructions. Some models may require a control-board jumper change. Do this only when explicitly instructed for that model.

Uninstall in OKCARE only removes the miner's GID binding; it does not uninstall OKMINER firmware. To restore official firmware, follow the card-flashing procedure for the specific model.

Configure Fans, Repair Channels, Repair Models, and Reset MAC

Each tool has different prerequisites:

  • Fan Settings: Only for miners running OKMINER firmware. Overclocking parameters in Miner Management in the App take priority. If fan parameters are set in the App, the OKCARE fan settings do not take effect.
  • Repair Channel: Use only when an upgrade from official firmware to OKMINER firmware fails. It repairs the online upgrade channel.
  • Repair Model: Use only when the wrong model of OKMINER firmware was installed. After repair, upgrade with the correct firmware.
  • Reset MAC: Use only for miners running OKMINER firmware when duplicate MAC addresses cause mixed data in the App.

These actions can change network, firmware, or hardware-identification information:

  1. Record the current IP, pool settings, and model first.
  2. Test one miner before running a batch operation.
  3. Do not force a repair, reset, or upgrade if model support is uncertain.