Not connected in the miner dashboard or mining software means the miner cannot currently reach the computer or server running OKPROXY.
Identify the Scope
| Symptom | Check First |
|---|---|
| All miners are disconnected | Whether OKPROXY is running, server network and DNS, a changed server IP, and firewall rules. |
| Only one or a few miners are disconnected | Their network, pool address, port, and miner configuration. |
Troubleshoot in Order
- Restart OKPROXY and confirm that the program or service is running.
- Confirm that the proxy server has Internet access and is not sleeping, hibernating, or shut down.
- Confirm that miners can reach the proxy server without guest isolation, VLAN, or firewall restrictions.
- Check the server's current LAN IPv4 address. If it changed after a restart or reconnection, update the pool address on the miners.
- Verify the address format, IP, and port, then save:
stratum+tcp://proxy-server-IP:port
- Check miner logs for connection errors. Wait for automatic reconnection and valid shares after changing settings.
Prevent Another Disconnection
- Assign a static LAN IP to the OKPROXY server.
- Disable automatic sleep and maintain stable power and network.
- Configure the firewall according to the proxy server operating system: on Windows, follow the OKPROXY for Windows guide to disable Windows Defender Firewall for both private and public networks; on Linux, follow the OKPROXY for Linux guide to allow only the required proxy ports. Do not expose proxy management services directly to the Internet.
If the issue continues, contact us with the miner model, system or firmware version, proxy server OS, OKPROXY version, pool address with public details hidden, and relevant logs.